Manuals
Redundancy
A redundant setup pairs a primary KLANG processor with a backup processor that holds the same show. The backup is named like the primary plus an underscore, for example KLANG(1) and KLANG(1_). KLANG:app recognises the pair, keeps the backup in sync with every change made on the primary, and lets you move all mixes to the backup when the primary fails. This page covers KLANG:app / KOS 6.0. To move every KLANG:app and KLANG:kontroller in the house with one button press, see Switch all devices between processors.
KLANG with the name of your processors as shown in CONFIG > CONNECT.Preparation: the same show on both processors
Set up your mixes on the primary processor first, then copy the show to the backup processor through KLANG:app.
- Connect to the primary processor.
- Go to
CONFIG > PRESETand select your show underOn KLANG(1). - Press
Transfer. The show is copied to this KLANG:app. - Connect to the backup processor.
- Go to
CONFIG > PRESETand select the same show underTHIS :app. Entries there carry the suffix(THIS APP). - Press
Transfer from App, orTransfer+Loadto load the show on the backup right away.
All preset functions are explained on the CONFIG > PRESET page.
Name the primary and the backup processor
The pairing works through the device names. The primary gets a name with a cascade index, KLANG(1). The backup gets the same name with an underscore after the index, KLANG(1_). See also Cascading KLANG Immersive Processors.
Primary processor
- Connect to the primary processor.
- Go to
CONFIG > SETTINGS > System > Set Device Name(also inCONFIG > INFO > Set Menu). - Enter
KLANGasDevice Nameand choose1asCascade Index. The preview line showsKLANG(1). - Press
SET.
Backup processor
The SET DEVICE NAME dialog only builds names with a plain cascade index, so the backup name is sent with one OSC command from KLANG:app. Connect to the backup processor, open CONFIG > APP > Custom & Macro OSC > Edit & Send and fill in the fields:
| Field | Value |
|---|---|
Target IP Address | processor (the connected backup processor) |
Receive Port | 9110 |
OSC Address | /KLANGfabrik/Hardware/UnitName |
Argument Type | s = String |
Argument | KLANG(1_) |
Press Save & SEND. The same command from a computer: KLANGosc <backup ip> 9110 /KLANGfabrik/Hardware/UnitName s "KLANG(1_)". The full OSC reference is at klang.com/osc.
Connect to the primary processor again. In CONFIG > CONNECT the backup processor is listed in grey below the primary.

Switch to the backup processor
If the primary processor is not available, there are three options:
- On each KLANG:app, go to
CONFIG > CONNECTand connect to the corresponding mix on the backup processor. - Make the backup the new primary: connect to the backup processor in Admin Mode, go to
CONFIG > SETTINGS > System > Set Device Name(also inCONFIG > INFO > Set Menu), enterKLANGasDevice Name, choose1asCascade Indexand pressSET. The name is nowKLANG(1)without the underscore, and all KLANG:apps and KLANG:kontrollers recognise the backup as the primary processor. - Move every device with one button press, and back again once the primary is repaired: see Switch all devices between processors (KLANG:app / KOS 6.0.8+).