Manuals

Redundancy

A redundant setup pairs a primary KLANG processor with a backup processor that holds the same show. The backup is named like the primary plus an underscore, for example KLANG(1) and KLANG(1_). KLANG:app recognises the pair, keeps the backup in sync with every change made on the primary, and lets you move all mixes to the backup when the primary fails. This page covers KLANG:app / KOS 6.0. To move every KLANG:app and KLANG:kontroller in the house with one button press, see Switch all devices between processors.

Requires Admin Mode. Replace KLANG with the name of your processors as shown in CONFIG > CONNECT.

Preparation: the same show on both processors

Set up your mixes on the primary processor first, then copy the show to the backup processor through KLANG:app.

  1. Connect to the primary processor.
  2. Go to CONFIG > PRESET and select your show under On KLANG(1).
  3. Press Transfer. The show is copied to this KLANG:app.
  4. Connect to the backup processor.
  5. Go to CONFIG > PRESET and select the same show under THIS :app. Entries there carry the suffix (THIS APP).
  6. Press Transfer from App, or Transfer+Load to load the show on the backup right away.

All preset functions are explained on the CONFIG > PRESET page.

Name the primary and the backup processor

The pairing works through the device names. The primary gets a name with a cascade index, KLANG(1). The backup gets the same name with an underscore after the index, KLANG(1_). See also Cascading KLANG Immersive Processors.

Primary processor

  1. Connect to the primary processor.
  2. Go to CONFIG > SETTINGS > System > Set Device Name (also in CONFIG > INFO > Set Menu).
  3. Enter KLANG as Device Name and choose 1 as Cascade Index. The preview line shows KLANG(1).
  4. Press SET.

Backup processor

The SET DEVICE NAME dialog only builds names with a plain cascade index, so the backup name is sent with one OSC command from KLANG:app. Connect to the backup processor, open CONFIG > APP > Custom & Macro OSC > Edit & Send and fill in the fields:

FieldValue
Target IP Addressprocessor (the connected backup processor)
Receive Port9110
OSC Address/KLANGfabrik/Hardware/UnitName
Argument Types = String
ArgumentKLANG(1_)

Press Save & SEND. The same command from a computer: KLANGosc <backup ip> 9110 /KLANGfabrik/Hardware/UnitName s "KLANG(1_)". The full OSC reference is at klang.com/osc.

Connect to the primary processor again. In CONFIG > CONNECT the backup processor is listed in grey below the primary.

CONFIG > CONNECT with the primary processor KLANG(1) in purple and the backup processor KLANG(1_) in grey below it
While you work on mixes or presets on the primary processor, every control message is also sent to the backup processor. Do not use the backup for anything else while the pair is active.

Switch to the backup processor

If the primary processor is not available, there are three options:

  1. On each KLANG:app, go to CONFIG > CONNECT and connect to the corresponding mix on the backup processor.
  2. Make the backup the new primary: connect to the backup processor in Admin Mode, go to CONFIG > SETTINGS > System > Set Device Name (also in CONFIG > INFO > Set Menu), enter KLANG as Device Name, choose 1 as Cascade Index and press SET. The name is now KLANG(1) without the underscore, and all KLANG:apps and KLANG:kontrollers recognise the backup as the primary processor.
  3. Move every device with one button press, and back again once the primary is repaired: see Switch all devices between processors (KLANG:app / KOS 6.0.8+).

Still Have Questions?